Home
About Us
Company Profile
History
Certificate
Privacy Policy
Factory View
Products
Inverter chiller
Air Cooled Industrial Chiller
1/4ton To 2ton Small Chiller
2.5ton To 60ton Scroll Chiller
Water Cooled Industrial Chiller
Air Cooled Screw Chiller
Water Cooled Screw Chiller
Air Cooled Glycol Chiller
1/5ton To 20ton Glycol Chiller-Scroll/Piston
7ton To 500ton Glycol Chiller-Screw Compressor
Water Cooled Glycol Chiller
1/5ton To 40ton Glycol Chiller-Scroll/Piston
8ton To 1000ton Glycol Chiller-Screw Compressor
Heating And Cooling Chiller
Mold Temperature Controller
Evaporative condenser chiller
Flooded screw chiller
Explosion proof chiller
Laser Chiller
Oil Chiller
Cooling Tower
Industrial Chiller
Video
Company Video
Products Video
Service & Support
User Q&A
OEM/ODM Services
Applications
Videos
News
Company News
Exhibitions
Industry News
Contact Us
Featured
Home
News
Company News
Chiller low pressure alarm
1. The low pressure of the chiller is very low, and the high pressure is very high, but there is no air leakage. At this time, check whether the temperature at both ends of the expansion valve and the filter dryer is consistent, or see whether the base of the expansion valve is frosty. Determine ...
Read More
Winter care tip for hair-raiser unit of measurement
Winter care measure for chiller As the temperature drop below 0 ° degree centigrade, it is crucial to return care of your hair-raiser unit of measurement during the winter calendar month. add antifreeze beforehand is necessity to prevent the cooling water from freeze, which could lead to ...
Read More
High voltage alarm 30AD troubleshooting steps
1. Check the pressure gauge; if it is higher than 24kg, the condenser has poor heat dissipation; if it is lower than 24kg, the high voltage pressure is broken; 2. Check for poor heat dissipation: a. Whether the fans are all running and there is no reverse rotation; if there is any reverse rotatio...
Read More
Compressor low pressure alarm
When the low pressure gauge of the chiller alarms There are two possibilities First, there is a refrigerant leak Second, there is a blockage in the system What should we do ? Fill some refrigerant, if the low pressure pressure gauge can come up, it means that the refrigerant is leaking, if the r...
Read More
HERO-TECH MACHINE RFQ
Water flow alarm Shell and tube evaporator has a water flow switch, check whether the water flow switch is faulty 1. The normally closed state is shown in the following figure. If it is normally closed, act step 3; 2. Normally open state is the following figure, if it is normally open state, the...
Read More
Do not force chiller running once it has alarm!
The chiller control system has kinds of protetion and relevant alarm to remind user or techician STOP CHILLER & CHECK THE PROBLEM. But mostly they ignore the alarm, only reset the alarm and continuously run the chiller, but that will lead big damage sometimes. 1. Flow rate alarm: if alarm sho...
Read More
Spring Festival Holiday 7th To 22nd Feb
Dear All, We will start holiday from 7th Feb for Spring Festival Holiday, and will start work on 23rd Feb. If anything urgent, please call us via phone number, +86 15920056387 Thanks and best regards, SHENZHEN HERO-TECH REFRIGERATION EQUIPMENT CO., LTD Add: Building 34, Dayangtian Industrial Park...
Read More
20th Anniversary Celebration
Happy Birthday to HERO-TECH GROUP On the date of 18th Aug, HERO-TECH was started as a trading company. 2010, SHENZHEN HERO-TECH started as a professional manufacturer of industrial refrigeration equipment. 2012, Longstar import and export company started as the second subsidiary corporation; 201...
Read More
Official Announcement
Read More
Hot Season For Water Chiller Orders
After short Spring Festival Holiday, we enter into a very busy working schedule. Because domestic customers already placed orders before holiday and needed after holiday finished, and oversea customers orders are coming in great numbers because of the summer is coming, especially our distributors...